GE / IP FANUC Series 90/30 In Stock

World's Largest Warehouse

of GE 90-30, Genius, and RX7i

Mon-Fri 8AM-5PM EST

IC693PRG300

Rated 4.5/5 Based on 14 ratings.

Rate your purchase of the IC693PRG300
Loading...

SKU 2176312  UPC 0458302419455

All product names, trademarks, brands and logos used on this site are the property of their respective owners. PDF Supply is not an authorized distributor, reseller or representative of the products featured on this website. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to in indicate any affiliation with or authorization by any rights holder.

PDF Supply is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply. Product comes with PDF Supply's 1-year, 2-year, or 3-year warranty.

New Surplus

$3590

1 In Stock

✓  3 Year PDF Supply Warranty

*What is New Surplus?

Ships .

Surplus New

$3410

Save $180

3 In Stock

✓  3 Year PDF Supply Warranty

*What is Surplus New?

Ships .

Reman

$1432

Save $2,158

9 In Stock

✓  2 Year PDF Supply Warranty

*What is Remanufactured?

Ships .

Repair Service

$1146

Save $2,444

5-10 Days

✓  2 Year PDF Supply Warranty

*What is Fast Repair?

Repair Completion:
5-10 Days

Common misspellings:
  • 1C693PRG300
  • IC693PRG3o0
  • IC693PRG30o
  • IC693PRG300

Product Description


The GE Fanuc IC693PRG300 is a G300 Hand-Held Programmer (HHP). This tool enables users to develop, debug, and monitor logic programs. Users can also monitor data tables and configure parameters for PLC units and I/O points. It uses the Statement List Language and it is possible to program this HHP with some models of the Series 90-30 PLC.   The Hand-Held Programmer cannot view or edit the user logic program in any Series 90-30 CPU with a model number of 350 and above.  For these CPUs, users can use Logicmaster 90-30, VersaPro or Control programming software.

There is a 15-pin D-type connector on the Series 90-30 PLC. This is located in the CPU baseplate of the power supply. This connector enables the HHP to connect to the CPU serial port. To physically connect them, use a 6-foot (2-meters) long cable (IC693CBL303). This will provide power to the HHP and also emits a signal that lets the PLC know a HHP is attached. It’s possible to connect or disconnect the HHP while the PLC is under power. In order to communicate with a PLC, the HHP does not need communications parameter configuration. This aids troubleshooting issues when there is a communication problem between the PC and a PLC.

Troubleshooting

Troubleshooting IC693PRG300

Troubleshooting information is available on IC693PRG300's website page; it also includes a datasheet user-manual and a wiring diagram.  

 

 

Repair your IC693PRG300

PDF Supply can repair your IC693PRG300 in 3-5 business days. And PDF Supply stands by all of its repairs with a 1 year customer satisfaction warranty.

Hand Held Programmer for 90-30

Description

Hand Held Programmer for 90-30

Resolution

Hand Held Programmer (HHP) for the 90-30 can be ordered under part#

IC693PRG300

Memory Card IC693ACC303 (Program Upload)

There are program restrictions

User logic program in CPU 350 and above cannot be viewed or edited by the HHP

 

The CPU in Series 90-30 Hand-Held Programmer (HHP IC693PRG300) To Be Used To Edit Data Values in %R Registers

Description

The Series 90-30 Hand-Held Programmer (HHP IC693PRG300) can be used to edit data values in %R registers in which CPUs.

Resolution

All 90-30 CPUs except the 374 *

 

Configuring a Profibus Field Control Module

Description

The Profibus IC670PBI001 BIU comes default from the factory set to the 'Autoconfiguration' mode.

Resolution

Steps to setup module

  1. Step dip switch 8 in the 'On' position (UP if module is mounted horizontally)
  2. Configure network id (1-126) with switches 1-7 (binary)
  3. Eg ID 3 set 1-2 to on position (Least significant bit switch 1)
  4. Cycle power the module with I/O connected
  5. Power and Ok light indication that unit is ready. Run light indicate that the unit is on the Bus.

Other option of configuring the module can be done with a 90-30 hand held programmer IC693PRG300 Hand Held Programmer (HHP) With Cable

Profibus Bus Interface Unit

Catalog Number; IC670PBI001-DG/EG

Firmware ID: CORE Version 2.60

COMM Version 3.50

GSD File: Version 3.30

Field Update Kit: 44A740056-G06

GSD Compatibility

GSD file, GEF_0534.GSD (Revision 3.30)

 

Customer Questions and Answers


  • Question:  What is an IC693PRG300?  Answer:  The IC693PRG300 is a Hand Held Programmer that has features which include, but are not limited to: creating a Statement List program (including insert, edit, and delete functions), making on-line program changes, searching a logic program for instructions and/or machine references, performing optional dual use checking of discrete output references when instructions are entered, and much, much more!
  • Question:  How many operating modes does IC693PRG300 have?  Answer:  IC693PRG300 has 4 major operating modes.
  • Question:  What are those operating modes?  Answer: 
    • Program mode: This mode is used to create, alter, monitor, and debug Statement List (SL) logic programs. Interaction (read, write, and verify) with a Series 90 Memory Card or EEPROM is also possible in this mode.
    • Data mode: This mode enables you to view and alter values in various reference tables. Numerous display formats are also supported.
    • Protection mode: This mode allows you to control access to (protect) a programmable logic controller, including program logic, reference data, and configuration information. The use of this mode is optional.
    • Configuration mode: In configuration mode, you can define the makeup of I/O modules in the PLC, including both those I/O modules already installed as well as those to be installed at a later time. 
  • Question:  What happens when you apply power to the PLC?  Answer:  When power is applied to the PLC, the Hand Held Programmer begins diagnostic tests on its hardware. And once these tests are successfully completed, the Hand Held Programmer can interact with the PLC.
  • Question:  What happens if my IC693PRG300 is not working properly?  Answer:  Your product may need repair, which we do here at PDF Supply.

For more information on the IC693PRG300 Hand Held Programmer of the GE 90-30 Series, please see the Datasheet Manual.

 

ST. LOUIS, Feb. 1, 2019 – Emerson today announced it has completed the purchase of Intelligent Platforms from General Electric.

Common related search terms: BatteryBuyConfigurationDatasheetEmersonManualPriceRepairSpecificationTroubleshootWiring

PDF Supply sells used surplus products. PDF Supply is not an authorized distributor, affiliate, or representative for the brands we carry. Products sold by PDF Supply come with PDF Supply’s 1-year, 2-year, or 3-year warranty and do not come with the original manufacturer’s warranty. Designated trademarks, brand names and brands appearing herein are the property of their respective owners. This website is not sanctioned or approved by any manufacturer or tradename listed.

Rockwell Disclaimer: The product is used surplus. PDF Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because PDF Supply is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, PDF Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. PDF Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. PDF Supply also makes no representations as to your right to install any such firmware on the product. PDF Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.