GE / IP FANUC Series 90/30 In Stock

World's Largest Warehouse

of GE 90-30, Genius, and RX7i

Mon-Fri 8AM-5PM EST

IC698RMX016

Rated 4.5/5 Based on 11 ratings.

Rate your purchase of the IC698RMX016
IC698RMX016 In Stock! RX7I REDUNDANT MEMORY EXCHANGE 16MB CONFORMAL COATED IC698R IC698RM IC698RMX P

SKU 2172437  UPC 0470821724278

All product names, trademarks, brands and logos used on this site are the property of their respective owners. PDF Supply is not an authorized distributor, reseller or representative of the products featured on this website. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to in indicate any affiliation with or authorization by any rights holder.

PDF Supply is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply. Product comes with PDF Supply's 1-year, 2-year, or 3-year warranty.

New Surplus

$4348

1 In Stock

✓  3 Year PDF Supply Warranty

*What is New Surplus?

Ships .

Reman

$1891

Save $2,457

46 In Stock

✓  2 Year PDF Supply Warranty

*What is Remanufactured?

Ships .

Repair Service

$1513

Save $2,835

5-10 Days

✓  2 Year PDF Supply Warranty

*What is Fast Repair?

Repair Completion:
5-10 Days

Other Available Revisions for the IC698RMX016 IC698RMX016-AAIC698RMX016-BAIC698RMX016-CBIC698RMX016-DCIC698RMX016-ED

Common misspellings:
  • 1C698RMX016
  • IC69bRMX016
  • IC698RMXo16
  • IC698RMX0l6
  • IC698RMX016

Technical Specifications for IC698RMX016

ManufacturerGE Fanuc
SeriesRX7i PACSystems
Part NumberIC698RMX016
Product TypeRedundancy Module
ApplicationsReflective network, hot standby CPU redundancy system
Reflective Memory128 MB
Optic Network Speed2.12 Gbaud
Transfer Rate2.1 GB/s
Hot InsertionSupported
Network Error DetectionSupported

Product Description

The GE Fanuc’s IC698RMX016 is a 16MB Redundant Memory Xchange for the Rx7I Pacsystem.  It has the following sizing: 6.299 inches widde x 9.187 inches high. It has 16MB of SDRAM user memory. The operating voltage from power supply is +5 V DC. Current requirements are 1.8A. The unit has a fiber optic LC type connector which, conforms to IEC 61754-20, and a zirconium ceramic ferrule. The maximum insertion loss is 0.35 dB with a return loss of -30dB. An acceptable temperature range is between -20°C and +85°CTo complete installation, you need to make sure you have all of the following: A PACSystems RX7i CPU with release 2.00 or later firmware; a PACSystems Rx7i CPU rack with power supply; a PC-compatible computer with CIMPLICITY Machine Edition – Logic Developer PLC, version 4.5 or later programming software and the necessary cables.

Note that in order to meet radiated emission standards, RX7i systems that include more than one Memory Xchange modules have to be installed in a conducting metal enclosure, or equivalent. Memory modules should only be installed in RX7i Rack 0 (main). It is advised that RMX modules are installed in slots 4 and 3 of the main rack. This provides the RMX modules VME interrupt request priority. Although such configuration is advisable, locating RMX modules in slots 4 and 3 is not strictly required. To install IC698RMX016 Redundant Memory Xchange, make sure the rack power is switched off. Next slide the module into the exact slot it was configured for in the system. Proceed to press the board in place without forcing it. Tighten faceplate top and bottom screws. Next make sure to connect cables to RX and TX connectors. The fiber optic cable should be routed from the TX connector to next node’s RX connector. Connect the that board’s TX cable to next node’s RX connector. Repeat until last node in the ring has its TX routed to the RX connector of the first node. Turn the power on.

The IC698RMX016 initially powers in a non-configured state where its optical transmitter is disabled. The Redundant Memory Xchange module will not operate on a network before the RX7i CPU sends the module a hardware configuration.  For the purpose of reflective memory operation, the user can choose to configure the following parameters: Redundant Transfer Mode, Node ID, Network Memory Offset, Rogue Master, and Interrupt enable. Note that if the Redundant Link operation is selected, the above-mentioned parameters will be set by the CPU and are therefore not configurable.  Note that when IC698RMX016 is used as a reflective memory module with a general purpose, additional functions that extend beyond the basic read and write operations, inclusive of reading interrupt status, enabling interrupts, reading parity errors, and enabling parity may be performed by user logic.

The IC698RMX016 Redundancy Memory Xchange Module comes in the RX7i PACSystems series by GE Fanuc Automation. The purpose of this module is to operate as a node on a reflective memory network or as a specific link that attaches 2 CPUs in a redundant system. It is compatible with the 5565 line of memory devices and it can determine the amount of data sharing between a PLC and other computing devices. Each of the nodes in the GE Fanuc Automation IC698RMX016 Redundancy Memory Xchange Module is connected in a daisy-chained loop mechanism by using fiber-optic cables. This connection method consists of connecting the first node to the second node and then the transmitter of the second node is connected to the receiver of the third node and so on until the loop has been connected to the first node and the loop is finally complete.
 

The GE Fanuc Automation IC698RMX016 Redundancy Memory Xchange Module is meant to be installed in a single slot in the RX7i PACSystems rack it comes with a reflective memory capacity of 16 MB, and the software configuration is performed to the old node parameters to prepare them for the new applications. Besides all of these functions, this module is also network-compatible with the VMIC 5565 reflective memory devices and it can be connected to them through multimode fiber cables that are up to 300 meters long. Some of the accessories included in this catalog to be used with the GE Fanuc Automation IC698RMX016 Redundancy Memory Xchange Module are a redundancy memory module, a control memory module, fiber-optic exchange cables, a lithium battery pack rack fan assembly, and different power supplies that can be used with this module to enhance its functioning.

Technical Information

 

Physical size

PCB: 6.299” W x 9.187” H

Packet size

Dynamic, automatically controlled by Memory Xchange module

User memory

16MB SDRAM

Operating voltage

+5VDC (from power supply)

Current requirements

1.8A

Connectors

â–         Fiber optic LC type, conforms to IEC 61754-20

â–         Zirconium ceramic ferrule

â–         Insertion loss: 0.35 dB (maximum)

â–         Return loss: -30dB

â–         Temperature Range: -20°C to +85°C

 

Troubleshooting

Troubleshooting IC698RMX016

Troubleshooting information is available on IC698RMX016's website page; it also includes a datasheet user-manual and a wiring diagram.

Repair your IC698RMX016

PDF Supply can repair your IC698RMX016 in 3-5 business days. And PDF Supply stands by all of its repairs with a 1 year customer satisfaction warranty.

 

Reflective Memory -- PC RFM to PACSystems RMX

Description

There is one red LED ON at the PC RFM card, but no communications with the PLC IC698RMX016 or IC695RMX128 modules.

After installing the Reflective Memory module and necessary optical cables, the PLC RMX module may still not be communicating with the PC RFM card.

Resolution

The PLC Reflective Memory Module (RMX016 and RMX128) can be configured as a Redundancy Only Link, or a Communications Only Link. They can not function as both at the same time.

There needs to be a slight change to the PLC RMX Module default configuration:

- Open the project in Proficy Machine Edition
- Go to HW configuration
- Locate RMX016 or RMX128 module
- Double-click to open its properties
- Locate "redundant link" entry
- Change this to "Disabled" to allow external communications
- Download the HW configuration to the PLC

The RMX module should now be working as an "ordinary" CMX module, which will now communicate with the RFM card in the PC.

Note that you should purchase a CMX card for PLC communications, as the RMX is designed to support PLC CPU redundancy. However it may be used as described above where CMX stock is not available or to maintain 1 part number for interchangeable spares.

 

 Customer Questions and Answers


  • Question:  What is an IC698RMX016?  Answer:  The IC698RMX016 is a Redundancy Memory Xchange module from the GE Fanuc RX7i Series. 
  • Question:  What does IC698RMX016 provide?  Answer:  This module operates as a node on a reflective memory network or as a dedicated link between CPUs in a redundant RX7i system. 
  • Question:  What is reflective memory technology/a reflective memory network?  Answer:  A reflective memory network can contain up to 256 nodes. Each node can be any reflective memory device that is compatible with the 5565 family. So, when data is written to 1 node, all nodes on the network are automatically updated with the new data. 
  • Question:  How are the nodes in a reflective memory network connected?  Answer:  Each node is connected in a daisy-chained loop using fiber optic cables. The transmitter of the first node is tied to the receiver of the second. The transmitter of the second node is tied to the receiver of the third, and so on, until the loop is completed back at the receiver of the first node. 
  • Question:  When used as a node, what does the IC698RMX016 do?  Answer:  When used as a node on a reflective memory network, the RMX module provides deterministic sharing of data among PLCs and other computing devices on a high-speed fiber optic network. 
  • Question:  When not in use, to which module is the IC698RMX016 functionally identical?  Answer:  IC698CMX016.
  • Question:  What should I do if my IC698RMX016 is not working properly?  Answer:  Your IC698RMX016 may need repair.

For more information on the IC698RMX016 Redundancy Memory Xchange Module of the GE Fanuc RX7i Series, please see the Datasheet User-Manual.

 

Release History

Catalog Number

Hardware Version

Firmware Version

IC698RMX016-ED

E

D

IC698RMX016-DC

D

C

IC698RMX016-CB

C

B

IC698RMX016-BA

B

A

IC698RMX016-AA

(Initial Release)

A

A

ST. LOUIS, Feb. 1, 2019 – Emerson today announced it has completed the purchase of Intelligent Platforms from General Electric.

Common related search terms: ConfigurationDatasheetEmersonManualPDFPLCPriceRepairSpecificationTroubleshootUser-ManualWiring

PDF Supply sells used surplus products. PDF Supply is not an authorized distributor, affiliate, or representative for the brands we carry. Products sold by PDF Supply come with PDF Supply’s 1-year, 2-year, or 3-year warranty and do not come with the original manufacturer’s warranty. Designated trademarks, brand names and brands appearing herein are the property of their respective owners. This website is not sanctioned or approved by any manufacturer or tradename listed.

Rockwell Disclaimer: The product is used surplus. PDF Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because PDF Supply is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, PDF Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. PDF Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. PDF Supply also makes no representations as to your right to install any such firmware on the product. PDF Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.