GE / IP FANUC Series 90/30 In Stock
SKU 2170332 UPC 0710754270375
All product names, trademarks, brands and logos used on this site are the property of their respective owners. PDF Supply is not an authorized distributor, reseller or representative of the products featured on this website. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to in indicate any affiliation with or authorization by any rights holder.
PDF Supply is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply. Product comes with PDF Supply's 1-year, 2-year, or 3-year warranty.
Other Available Revisions for the IC698CPE020 IC698CPE020-AAIC698CPE020-BAIC698CPE020-BCIC698CPE020-CCIC698CPE020-CDIC698CPE020-CEIC698CPE020-DEIC698CPE020-DFIC698CPE020-DGIC698CPE020-DHIC698CPE020-EJIC698CPE020-EKIC698CPE020-FLIC698CPE020-GMIC698CPE020-GNIC698CPE020-GPIC698CPE020-HPIC698CPE020-HQIC698CPE020-JQIC698CPE020-JRIC698CPE020-JSIC698CPE020-JTIC698CPE020-JUIC698CPE020-JVIC698CPE020-JWIC698CPE020-JXIC698CPE020-JYIC698CPE020-JZIC698CPE020-KAAIC698CPE020-KZIC698CPE020-Programming Software
Manufactured by GE Automation, the IC698CPE020 is a CPU from the PACSystems RX7i series. It is capable of real-time machine control and communicates with other rack modules via a standard VME backplane. Operation and control of the IC698CPE020 is accomplished by a connected computer or by an on-board three-position switch, which can be disabled if desired.
This device has a 700MHz Pentium III floating point microprocessor. Standard execution speeds for this processor are 0.14ms for every 1000 Boolean contacts. Ten megabytes of volatile memory (RAM) and 10 megabytes of flash memory (NVRAM) are available for use. A CMOS battery is required to support volatile memory. Flash memory is non-volatile. RAM and NVRAM can be used for user data, programming configuration, storing symbolic variables, and any information associated with the register. The operating system firmware is also stored in NVRAM. To update firmware, simply connect the IC698CPE020 to a computer using the proper serial port and run the update software.
Follow the procedures outlined in the manual while installing. Record the device’s MAC address. Power off the rack. In rack slot one, insert the IC698CPE020. Connect the device to the Ethernet LAN. Restore rack power. Connect the CMOS battery.
The IC698CPE020 has three serial ports and two Ethernet ports. For Ethernet connections, a category 5 shielded or unshielded RJ-45 twisted pair cable is needed, as well as TCP/IP configuration. Supported serial ports include RS-232 and RS-485. The third serial port is a station manager port.
Select features of this device include support for 512 program blocks, ladder diagram and C programming, symbolic variable support, modification testing modes, and the ability to monitor system data over a network. Note: Up to 16 web and FTP server connections are possible when using web monitoring.
Processing Speed: | 700 MHz |
CPU Memory: | 10 Mbytes |
Floating Point: | Yes |
Serial Ports: | 3 |
Serial Protocols: | Modbus RTU Slave, SNP, Serial I/O |
Embedded Comms: | RS-232, RS-486. Ethernet interface |
Battery Memory retention |
For battery selection, installation and estimated life, refer to the PACSystems Controller Battery and Energy Pack Manual, GFK-2741. |
Program storage |
Up to 10 Mbytes of battery-backed RAM 10 Mbytes of non-volatile flash user memory |
Power requirements CPE010 CPE020 |
+5 VDC: 3.2 Amps nominal +12 VDC: 0.042 Amps nominal -12 VDC: 0.008 Amps nominal +5 VDC: 4.5 Amps nominal +12 VDC: 0.042 Amps nominal -12 VDC: 0.008 Amps nominal |
Operating temperature |
CPE020: 0 to 60°C (32°F to 140°F) with fan tray, required |
Floating point |
Yes |
Boolean execution speed, typical CPE010 CPE020 |
0.33ms per 1000 Boolean contacts/coils 0.14ms per 1000 Boolean contacts/coils |
Time of Day Clock accuracy |
Maximum of 9 seconds per day |
Elapsed Time Clock (internal timing) accuracy |
0.01% maximum |
Embedded communications |
RS-232, RS-485, Ethernet interface |
Ethernet Ports |
Embedded auto-sensing 10/100 Mbps half/full duplex Ethernet interface |
Serial protocols supported |
Modbus RTU Slave, SNP, Serial I/O |
VME Compatibility |
System designed to support the VME64 standard ANSI/VITA 1 |
Program blocks |
Up to 512 program blocks. Maximum size for a block is 128KB. |
Memory |
%I and %Q: 32Kbits for discrete %AI and %AQ: configurable up to 32Kwords %W: configurable up the maximum available user RAM Symbolic: configurable up to 10Mbytes |
Ethernet Interface Specifications |
|
Web-based data monitoring |
Up to 16 web server and FTP connections (combined) |
Ethernet data rate |
10Mb/sec and 100Mb/sec |
Physical interface |
10BaseT RJ45 |
WinLoader support |
Yes |
Number of EGD configuration-based pages |
255 |
Time synchronization |
SNTP |
Selective consumption of EGD |
Yes |
Load EGD configuration from CPU to programmer |
Yes |
Remote Station Manager over UDP |
Yes |
Local Station Manager (RS-232) |
Dedicated RS-232 port |
Configurable Advanced User Parameters |
Yes |
Troubleshooting IC698CPE020
Troubleshooting information is available on IC698CPE020's website page; it also includes a datasheet user-manual and a wiring diagram.
Repair your IC698CPE020
PDF Supply can repair your IC698CPE020 in 3-5 business days. And PDF Supply stands by all of its repairs with a 1 year customer satisfaction warranty.
For more information on the IC698CPE020 Central Processing Unit of the GE Fanuc RX7i Series, please see the Datasheet User-Manual.
Revision | Date | CPU Version | Ethernet Version |
CPE020-KAA | May. 13 | 6.75 | 6.2 |
CPE010-JX | May. 13 | 6.75 | 6.2 |
-KZ | Jun. 12 | 6.75 | 6.13 |
-JZ | Apr. 12 | 6.75 | 6.13 |
-JY | Feb. 12 | 6.75 | 6.12 |
-JX | Nov. 11 | 6.75 | 6.1 |
-JW | Jul. 11 | 6.71 | 6.1 |
-JV | Mar. 10 | 6.01 | 6 |
-JU | Sep. 09 | 6 | 6 |
-JT | Dec. 08 | 5.5 | 5.51 |
-JS | May. 08 | 5.5 | 5.5 |
-JR | Dec. 07 | 5 | 5.01 |
-JQ | Oct. 07 | 5 | 5 |
-HQ | Aug. 07 | 5 | 5 |
-HP | Jul. 07 | 4.02 | 4 |
-GP | Dec. 06 | 4.02 | 4 |
-GN | Sep. 06 | 4 | 4 |
-GM | May. 06 | 3.5 | 3.81 |
-FL | Nov. 05 | 3.5 | 3.6 |
-EK | Sep. 05 | 3.5 | 3 |
-EJ | Jul. 05 | 3.11 | 3 |
-DH | Apr. 05 | 3.1 | 3 |
-DG | Apr. 05 | 3 | 3 |
-DF | Feb. 05 | 2.58 | 2.57 |
-DE | Nov. 04 | 2.57 | 2.57 |
-DE | Sep. 04 | 2.56 | 2.56 |
-CE | Sep. 04 | 2.56 | 2.56 |
-CD | Aug. 04 | 1.63 | 1.6 |
-CD | Jul. 04 | 1.62 | 1.6 |
-CD | Jun. 04 | 1.61 | 1.61 |
-CC | Nov. 04 | 1.6 | 1.6 |
-BC | Sep. 04 | 1.6 | 1.6 |
-BB | Jun. 04 | 1.5 | 1.5 |
-BA | Jun. 04 | 1 | 1 |
-AA | Jun. 03 | 1 | 1 |
PDFsupply Tech
The IC698CPE020 is part of the RX7i family and has a processing speed of 700MHz with embedded Ethernet interface. This processing speed is superior to the IC698CPE010 which has a speed of 300MHz.
Common related search terms: ConfigurationDatasheet, Emerson, Manual, PDF, PLC, Price, Repair, Specification, Troubleshoot, User-Manual, Wiring,
PDF Supply sells used surplus products. PDF Supply is not an authorized distributor, affiliate, or representative for the brands we carry. Products sold by PDF Supply come with PDF Supply’s 1-year, 2-year, or 3-year warranty and do not come with the original manufacturer’s warranty. Designated trademarks, brand names and brands appearing herein are the property of their respective owners. This website is not sanctioned or approved by any manufacturer or tradename listed.
Rockwell Disclaimer: The product is used surplus. PDF Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because PDF Supply is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, PDF Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. PDF Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. PDF Supply also makes no representations as to your right to install any such firmware on the product. PDF Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.