GE / IP FANUC Series 90/30 In Stock
SKU 2171133 UPC 0460682661799
All product names, trademarks, brands and logos used on this site are the property of their respective owners. PDF Supply is not an authorized distributor, reseller or representative of the products featured on this website. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to in indicate any affiliation with or authorization by any rights holder.
PDF Supply is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply. Product comes with PDF Supply's 1-year, 2-year, or 3-year warranty.
Other Available Revisions for the IC695PNC001 IC695PNC001-AAIC695PNC001-ABIC695PNC001-ACIC695PNC001-ADIC695PNC001-AEIC695PNC001-AFIC695PNC001-AGIC695PNC001-AHIC695PNC001-AJIC695PNC001-AKIC695PNC001-ALIC695PNC001-AMIC695PNC001-ANIC695PNC001-LT
The IC695PNC001 is a PACSystems PROFINET Controller Module from the GE Fanuc RX3i Series. This module connects a PACSystem RX3i controller to a high-speed PROFINET local area network. See specifications for this unit on IC695PNC001's website page.
Module Type: | PROFINET Controller |
Number of Slots: | 1 (single Slot) |
Backplane Support: | Universal only |
Protocol Support: | PROFINET Version 2.2 General Class A |
Communication Ports: | Micro USB for system setup and diagnostics only |
Internal Power: | 0.5A @ 3.3 VDC, 1.5A @ 5 VDC |
PROFINET Support |
PROFINET Version 2.2 General Class A I/O-Controller. Redundantly controlled operation conforms to PROFINET V2.3 Type S-2 System Redundancy. |
RX3i CPU Compatibility |
See compatibility section below. |
Power Requirements |
3.3 Vdc: 0.5 A with no SFP devices installed 1.2 A maximum (two SFP devices installed, 0.35 A per SFP device) |
5 Vdc: 1.5 A maximum |
|
Operating Temperature Range |
0 to 60°C maximum surrounding air temperature without a fan. A lower maximum temperature may be required depending on PNC001 location and SFP population. Refer to the section, Operating Range for Air Temperature in PACSystems RX3i PROFINET I/O Controller Manual, GFK-2571. |
Number of Port Connectors |
Two RJ-45 and two SFP Cages (SFP devices not included, available separately) |
Micro USB Connector |
One, for communication with a computer using Command Line Interface. |
LAN |
IEEE 802.2 Logical Link Control Class I IEEE 802.3 CSMA/CD Medium Access Control 10/100/1000 Mbps |
Maximum I/O Memory |
128 Kbytes of combined input/output memory per PROFINET Controller |
CPU Status Bits |
32 |
PROFINET I/O Device Data Update Rates on the PROFINET LAN |
Configurable: 1 ms, 2 ms, 4 ms, 8 ms, 16 ms, 32 ms, 64 ms, 128 ms, 256 ms and 512 ms |
Number of IP addresses |
One |
Number of MAC Addresses |
Five. One per external port and one internal. |
System Maximum Limits |
|
PNCs per RX3i CPU |
Four. Must be located in main rack. Cannot be located in a remote node. |
I/O-Devices per I/O-Controller |
128 per PROFINET Controller (Configured as an MRP Manager, the PNC001 is limited to managing no more than 63 MRP Clients). |
I/O-Devices per Network |
255 per network, spread across up to 8 IO-Controllers |
I/O-Devices per RX3i CPU |
255 per RX3i CPU, spread across up to 4 PROFINET Controllers |
I/O-Controllers per network |
8 |
Number of PROFINET Slots per device |
256 |
Number of PROFINET Subslots per slot |
256 |
Number of PROFINET Submodules per RX3i CPU |
2048 |
Programmer Limits |
|
Number of I/O-Controllers |
128 (32 RX3i CPU targets × 4 IO-Controllers per RX3i CPU) |
Number of I/O-Devices |
4080 (255 per network × 16 PROFINET networks) |
Total number of devices |
4208 (does not include backplanes, power supplies, or I/O modules) |
Hot-swappable |
Yes |
Troubleshooting IC695PNC001
Troubleshooting information is available on IC695PNC001's website page; it also includes a datasheet user-manual and a wiring diagram.
Repair your IC695PNC001
PDF Supply can repair your IC695PNC001 in 3-5 business days. And PDF Supply stands by all of its repairs with a 1 year customer satisfaction warranty.
For more information on the IC695PNC001 PACSystems PROFINET Controller Module of the GE Fanuc RX3i Series, please see the Datasheet User-Manual.
Version |
Firmware Revision |
Date |
Comments |
IC695PNC001-AN |
2.27 |
May 2017 |
Adds support for the Genius Communication Gateway’s (GCG001) Switch BSM and Enable/Disable Outputs COMMREQs. |
IC695PNC001-AM |
2.26 |
Jun 2016 |
Supports the Remote Get HART Device Information COMMREQ. Information from a HART device connected to an RX3i Analog Module in an IC695PNS001 RX3i PROFINET Scanner may be read into the user application using the Remote Get HART Device Information COMMREQ. |
IC695PNC001-AL |
2.25 |
Nov 2015 |
Supports extended PROFINET device Subslot Numbers in order to support additional 3rd party devices. The maximum Subslot Number has been increased from 255 to 21845. |
IC695PNC001-AK |
2.20 |
May 2015 |
Added support for HART® Pass Through feature set over PROFINET . A HART capable PROFINET scanner (IC695PNS001 or IC695CEP001) must also be employed to support the HART capable RX3i analog modules over PROFINET. The CPU used in the application must also contain firmware which supports HART Pass Through. |
IC695PNC001-AJ |
2.11 |
Feb 2015 |
Increased number of PROFINET Devices that PNC001 can control from 64 to 128. Still limited to 63 devices in an MRP Ring if the PNC001 is the MRP Ring Manager. Added new SFP OK status bits to existing PNC001 status dword. Introduced new Critical Network Port diagnostic fault configuration and logging. Configuring ports as critical also forces Copper ports to 100 Mbps. |
IC695PNC001-AH |
2.05 |
Jun 2014 |
Adds support for COMMREQs required by the Genius Communication Gateway (GCG001) module. |
IC695PNC001-AG |
2.00 |
Dec 2013 |
Adds remote PROFINET IO to PACSystems RX3i Hot Standby Redundancy systems. Also adds MRP status bits. For details, see New Features and Enhancements below. |
IC695PNC001-AF |
1.23 |
Aug 2013 |
Corrects issue storing PROFINET device configuration greater than 64K bytes in size. For details, see RX3i PROFINET Controller IPI, GFK-2573F. |
IC695PNC001-AE |
1.22 |
Jul 2013 |
Corrects an issue where, in some configurations, the PNC001 entered a mode that caused it to repeatedly power up. |
IC695PNC001-AD |
1.21 |
Jul 2012 |
Addresses a power-up issue affecting the following revisions IC695PNC001-AB and IC695PNC001-AC. Although no units that exhibited this issue were shipped, it is recommended to update firmware to prevent the possibility of encountering a power up issue in the field. |
IC695PNC001-AC |
1.20 |
Mar 2012 |
Adds support for up to 255 PROFINET IO Devices per RX3i CPU. |
IC695PNC001-AB |
1.10 |
Dec 2011 |
Adds support for SNMP and LLDP standards to facilitate network management. Provides enhanced Revision Information in the Explore PROFINET Networks tool. |
IC695PNC001-AA |
1.00 |
Jun 2011 |
Initial release. Supports GSDML Version 2.2 and earlier. |
Common related search terms: BatteryBuy, Configuration, Datasheet, Dimension, Emerson, Fanuc, Firmware, GE-Fanuc, Manual, PDF, PLC, Price, Repair, Specification, Troubleshoot, User-Manual, Wiring,
PDF Supply sells used surplus products. PDF Supply is not an authorized distributor, affiliate, or representative for the brands we carry. Products sold by PDF Supply come with PDF Supply’s 1-year, 2-year, or 3-year warranty and do not come with the original manufacturer’s warranty. Designated trademarks, brand names and brands appearing herein are the property of their respective owners. This website is not sanctioned or approved by any manufacturer or tradename listed.
Rockwell Disclaimer: The product is used surplus. PDF Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because PDF Supply is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, PDF Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. PDF Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. PDF Supply also makes no representations as to your right to install any such firmware on the product. PDF Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.