All product names, trademarks, brands and logos used on this site are the property of their respective owners. PDF Supply is not an authorized distributor, reseller or representative of the products featured on this website. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to in indicate any affiliation with or authorization by any rights holder.
PDF Supply is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply. Product comes with PDF Supply's 1-year, 2-year, or 3-year warranty.
Other Available Revisions for the IC695EDS001 IC695EDS001-AAIC695EDS001-BBIC695EDS001-BCIC695EDS001-CDIC695EDS001-CEIC695EDS001-LT
The IC695EDS001 is a DNP3 Slave/Outstation Module from the GE Fanuc RX3i Series. This module connects an RX3i controller to a DNP3 network using a standard Ethernet TCP/IP connection scheme. See specifications for this unit on IC695EDS001's website page.
Module Name |
PACSystems RX3i DNP3 Outstation Module |
Catalog |
IC695EDS001 |
Protocol Supported |
DNP3 Outstation |
CPU Compatibility |
CPU320/CPU315, CPU310/CMU310/NIU001, CRU320/CRU320QP, CPE310 firmware version 6.0 or later |
Programmer Compatibility |
Proficy Machine Edition 8.5 SIM7 or later |
Connectors |
Station Manager (RS-232) Port: 9-pin female D-connector |
Two 10BaseT / 100BaseTX Ports: 8-pin female shielded RJ-45 |
|
LAN |
IEEE 802.2 Logical Link Control Class I |
IEEE 802.3 CSMA/CD Medium Access Control 10/100 Mbps |
|
Number of IP addresses |
One |
Number of Ethernet Port Connectors |
Two: both 10BaseT / 100BaseTX with auto-sensing RJ-45 connection. |
Embedded Ethernet Switch |
Yes – Allows daisy chaining of Ethernet nodes. Ring networks not permitted. |
Serial Port |
Station Manager Port: RS-232 DCE, 1200 - 115200 bps. |
Modules per RX3i CPU |
4 (max - depends on power and slots available) |
No. of DNP3 Masters supported per module |
8 per module (max) |
No. of DNP3 Masters supported per RX3i CPU |
32 per RX3i CPU (max) |
No. of DNP3 points per module |
12,072 |
No. of DNP3 events per module |
20,000 |
Network Topology supported |
Star, Line, Daisy Chain |
RX3i Slot Location |
Any I/O Slot in Main Rack. |
Hot Swappable |
Yes. Refer to Chapter 2 of PACSystems RX3i System Manual, GFK-2314E or later for instructions & restrictions. |
Time Synchronization |
SNTP Client, DNP3 Time Synchronization |
Power Requirements |
3.3Vdc: 840 mA maximum |
5Vdc: 614 mA maximum |
Troubleshooting IC695EDS001
Troubleshooting information is available on IC695EDS001's website page; it also includes a datasheet user-manual and a wiring diagram.
Repair your IC695EDS001
PDF Supply can repair your IC695EDS001 in 3-5 business days. And PDF Supply stands by all of its repairs with a 1 year customer satisfaction warranty.
For more information on the IC695EDS001 DNP3 Slave/Outstation Module of the GE Fanuc RX3i Series, please see the Datasheet User-Manual.
Catalog Number |
Firmware Version |
Date |
Comments |
IC695EDS001-CE |
Firmware 6.40 /1.40 |
Feb 2016 |
An enhancement was made to prevent the module from becoming unresponsive and requiring a power cycle if it was subjected to heavy network storm traffic. |
IC695EDS001-CD |
Firmware 6.31 /1.30
Boot 3.71 |
Dec 2015 |
This hardware release addresses an issue identified, where the module can unexpectedly go into firmware update mode (Ethernet OK, LAN OK, and Log Empty LEDs blink in unison). While in firmware update mode, the module is unresponsive to Ethernet traffic. There are no changes to form, fit, or function.
This Firmware provides enhancements to configure the Event Buffer size separately for Digital Inputs (BI – Binary Inputs and BO – Binary Output status) and Analog Inputs ( AI – Analog Inputs and AOS – Analog Output status) and also support specific DNP3 object variations. This also fixes issue with module going unexpectedly in firmware update mode, as part of the Web upgrade kit. |
IC695EDS001-BC |
1.20 |
Jul 2015 |
This firmware release fixes the issue related to IIN Bits indicating Class1 and Clas2 Data Available status to DNP3 Master. The firmware also corrects the control code for Close and Trip Control (Close=101) and (Trip =110) in the CROB Control DWORD to be consistent with description in User manual –Section 6.9.2. |
IC695EDS001-BB |
1.10 |
Apr 2015 |
Added a feature to support different control codes like PULSE ON/OFF, CLOSE, TRIP and LATCH ON/OFF for the CROB Control objects. This also enhanced the Quality functionality for ensuring that events are generated when quality is offline, and appropriate quality status is updated. This hardware release addresses a component obsolescence issue. There are no changes to form, fit, or function. |
IC695EDS001-AA |
1.00 |
Oct 2014 |
Initial release. |
Common related search terms: BatteryBuy, Configuration, Datasheet, Dimension, Emerson, Fanuc, Firmware, GE, GE-Fanuc, Manual, PDF, PLC, Price, Repair, Specification, Troubleshoot, User-Manual, Wiring,
PDF Supply sells used surplus products. PDF Supply is not an authorized distributor, affiliate, or representative for the brands we carry. Products sold by PDF Supply come with PDF Supply’s 1-year, 2-year, or 3-year warranty and do not come with the original manufacturer’s warranty. Designated trademarks, brand names and brands appearing herein are the property of their respective owners. This website is not sanctioned or approved by any manufacturer or tradename listed.
Rockwell Disclaimer: The product is used surplus. PDF Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because PDF Supply is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, PDF Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. PDF Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. PDF Supply also makes no representations as to your right to install any such firmware on the product. PDF Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.