All product names, trademarks, brands and logos used on this site are the property of their respective owners. PDF Supply is not an authorized distributor, reseller or representative of the products featured on this website. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to in indicate any affiliation with or authorization by any rights holder.
PDF Supply is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply. Product comes with PDF Supply's 1-year, 2-year, or 3-year warranty.
Other Available Revisions for the IC695ALG112 IC695ALG112-AAIC695ALG112-BAIC695ALG112-CAIC695ALG112-DAIC695ALG112-EAIC695ALG112-FBIC695ALG112-LT
Manufacturer | GE Fanuc |
---|---|
Series | RX3i PACSystems |
Part Number | IC695ALG112 |
Product Type | Input Module |
Module Type | Analog |
Slots Needed for Installation | 1 |
Voltage Operation | Supported |
Current Operation | Supported |
Jumpers | Not Required |
Configurable Software | Supported |
The IC695ALG112 is an 12-Channel, Isolated, Analog Input module from the GE Fanuc RX3i Series. The IC695ALG112 provides 12 isolated input channels. The module must be located in an RX3i Universal Backplane. It requires an RX3i CPU firmware version 5.0 or later. See specifications for this unit on IC695ALG112's website page.
Module Type: | Analog Input |
No of Inputs: | 12 Isolated Inputs |
Internal Power: | 3.3V: 600mA; 5V: 800 mA |
Number of Slots: | 1 (single slot) |
Voltage Range: | 0 to 10V, +/-10V, 0 to 5V, +/-5V, 1 to 5V |
Current Range: | 0-20 mA, 4-20 mA, +/-20 mA |
The IC695ALG112 input module is an industrial analog input module from the GE Fanuc RX3i PACSystems product line. It hosts 12 input channels that are all isolated. The IC695ALG112 analog input module only needs 1 slot in an RX3i PACSystems backplane to be securely installed, but it can only be installed specifically in an RX3i universal backplane. The firmware that the IC695ALG112 analog input module uses needs to be RX3i CPU firmware that is version 5.0 or later. This analog input module is designed to be flexible and it can run on both voltage and current, and it can also be programmed with different voltage or current ranges depending on the applications that it is intended for.
The voltage ranges that the GE Fanuc RX3i PACSystems IC695ALG112 analog input module can operate with are ranges of 0 Volts to 10 Volts, -10 Volts to +10 Volts, 0 Volts to 5 Volts, -5 Volts to +5 Volts, and 1 Volt to 5 Volts. The operating current ranges that the IC695ALG112 analog input module can support are -20 milliamps to +20 milliamps, 0 milliamps to 20 milliamps, and 4 milliamps to 20 milliamps. The software in the IC695ALG112 analog input module is completely configurable by the users, and this module does not need a jumper for setup. This module also has diagnostics features that scan it every time it starts up and during operation to detect errors as quickly as possible and allow the operators to intervene and prevent severe component damage, serious injury, and lost data.
Input Ranges |
Current: 0 to 20mA, 4 to 20mA, +/- 20mA Voltage: +/- 10V, 0 to 10V, +/- 5V, 0 to 5V, 1 to 5V |
||
Power Requirements (from the backplane) |
ALG106: 230 mA maximum @ 5.0V +5% / -2.5%, 320 mA maximum @ 3.3V +5% / -3% ALG112 490 mA maximum @ 5.0V +5% / - 2.5%, 310 mA maximum @ 3.3V +5% / - 3% |
||
Power Dissipation within Module |
IC695ALG106: 2.97 watts maximum; with 20mA inputs on all 6 channels IC695ALG112: 4.89 watts maximum with 20mA inputs on all 12 channels |
||
Thermal Derating |
No derating |
||
Resolution |
16 bit ADC converted to Floating Point or Integer |
||
Input Data Format |
Configurable as floating point IEEE 32 bit or 16-bit integer in a 32-bit field |
||
Filter Options |
8Hz, 12Hz, 16Hz, 40Hz, 250Hz, 1000Hz |
||
Input Impedance |
>500 Kohm voltage inputs |
||
Current Input Resistance |
250 ohms +/- 1% |
||
Open Circuit Detection time |
1 second maximum |
||
Overvoltage |
+/-35 VDC continuous, maximum |
||
Overcurrent |
+/-35mA continuous, maximum |
||
Normal Mode Noise Rejection (dB) |
|
At 50Hz |
At 60Hz |
8 Hz filter |
90 |
75 |
|
12 Hz filter |
75 |
80 |
|
16 Hz filter |
35 |
75 |
|
Common Mode Noise Rejection |
100dB minimum @ 50/60 Hz with 8 Hz filter 100dB minimum @ 50/60 Hz with 12 Hz filter |
||
Channel-Channel DC Crosstalk |
-70 dB minimum |
||
Isolation Voltage terminal block to backplane/chassis and channel to channel |
I-coupler, transformer isolated 250 VAC continuous/1500 VAC for 1 minute |
||
Analog Step Change Response |
The analog input will settle to 0.1% of its final value within 1.7mS for a step change on the input pins of the module. (Any digital filtering is in addition to this time.) |
||
Digital Filtering Settling Time (milliseconds) |
The settling time depends on the configured filter time. 8 Hz Filter: 127 mS 12 Hz Filter: 67 mS 16 Hz Filter: 56 mS 40 Hz Filter: 21 mS 250 Hz Filter: 3.1 mS 1000 Hz Filter: 0 mS (no digital filtering; analog front-end filter only) |
||
Analog Module Scan Time (milliseconds) |
The modules provide a new sample every 1mS, regardless of the digital filtering selected. See Digital Filtering Settling Time for the amount of time required to have settled data. |
||
Calibrated Accuracy |
0.1 % of range at 25°C 0.2 % of range over entire temperature span In the presence of severe RF interference (IC 801-3, 10V/M), accuracy may be degraded by 2.0% of range. |
||
Calibration Interval |
12 months typical to meet accuracy specifications over time. Offset can be applied as a periodic calibration adjustment. |
Troubleshooting IC695ALG112
Troubleshooting information is available on IC695ALG112's website page; it also includes a datasheet user-manual and a wiring diagram.
Repair your IC695ALG112
PDF Supply can repair your IC695ALG112 in 3-5 business days. And PDF Supply stands by all of its repairs with a 1 year customer satisfaction warranty.
For more information on the IC695ALG112 12-Channel, Isolated, Analog Input Module of the GE Fanuc RX3i Series, please see the Datasheet User-Manual.
Version |
Firmware Revision |
Date |
Description |
IC695ALG106-FC |
2.01 |
September 2017 |
FW update to correct PCI ID value reported to allow use of the ALG106 in remote PNS001 controlled racks. |
IC695ALG106-FB IC695ALG112-FB |
2.00 |
July 2017 |
New hardware and firmware to address component obsolescence and to obtain EU RoHS compliance |
IC695ALG106-EA IC695ALG112-EA |
1.00 |
November 2013 |
Hardware design updated to address component obsolescence. No change in functionality, performance, or compatibility. Product labeling and documentation of backplane power consumption revised as a result of UL testing. |
IC695ALG106-DA IC695ALG112-DA |
1.00 |
September 2010 |
Label change only. No change in functionality, performance or compatibility. |
IC695ALG106-CA IC695ALG112-CA |
1.00 |
July 2009 |
Modified the terminal block detector switch to increase the size of the switch lever. The increased size of the switch lever allows additional tolerance to assure contact with the terminal block actuator. |
IC695ALG106-BA IC695ALG112-BA |
1.00 |
June 2009 |
UL approval |
IC695ALG106-AA IC695ALG112-AA |
1.00 |
October 2007 |
Initial Release |
Common related search terms: BatteryBuy, Configuration, Datasheet, Dimension, Emerson, Fanuc, Firmware, GE, GE-Fanuc, Manual, PDF, PLC, Price, Repair, Specification, Troubleshoot, User-Manual, Wiring,
PDF Supply sells used surplus products. PDF Supply is not an authorized distributor, affiliate, or representative for the brands we carry. Products sold by PDF Supply come with PDF Supply’s 1-year, 2-year, or 3-year warranty and do not come with the original manufacturer’s warranty. Designated trademarks, brand names and brands appearing herein are the property of their respective owners. This website is not sanctioned or approved by any manufacturer or tradename listed.
Rockwell Disclaimer: The product is used surplus. PDF Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because PDF Supply is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, PDF Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. PDF Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. PDF Supply also makes no representations as to your right to install any such firmware on the product. PDF Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.