GE / IP FANUC Series 90/30 In Stock

World's Largest Warehouse

of GE 90-30, Genius, and RX7i

Mon-Fri 8AM-5PM EST

IC660BBS102

Rated 4.8/5 Based on 21 ratings.

Rate your purchase of the IC660BBS102
IC660BBS102 In Stock! GENIUS Block 115Vac/125Vdc IC660B IC660BB IC660BBS PDFsupply also repairs GE I

SKU 2175155  UPC 044756951858

All product names, trademarks, brands and logos used on this site are the property of their respective owners. PDF Supply is not an authorized distributor, reseller or representative of the products featured on this website. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to in indicate any affiliation with or authorization by any rights holder.

PDF Supply is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply. Product comes with PDF Supply's 1-year, 2-year, or 3-year warranty.

Surplus New

$4095

1 In Stock

✓  3 Year PDF Supply Warranty

*What is Surplus New?

Ships .

Reman

$3306

Save $789

51 In Stock

✓  2 Year PDF Supply Warranty

*What is Remanufactured?

Ships .

Repair Service

$2645

Save $1,450

5-10 Days

✓  2 Year PDF Supply Warranty

*What is Fast Repair?

Repair Completion:
5-10 Days

Common misspellings:
  • 1C660BBS102
  • IC66oBBS102
  • IC6608BS102
  • IC660B8S102
  • IC660BBSl02
  • IC660BBS1o2
  • IC660BBS102

Technical Specifications for IC660BBS102

ManufacturerGE Fanuc
SeriesGenius I/O
Part NumberIC660BBS102
Product TypeOutput Block
Number of Outputs8
Number of Output Groups4 Groups of 2
Voltage TypeAC and DC
Nominal Voltage115 Volts AC, 125 Volts DC
Weight4 Pounds
Dimensions8.8 x 3.3 x 3.9 Inches
Operating Temperature32 to 140 degrees Fahrenheit
Storage Temperature-40 to 212 degrees Fahrenheit
Diagnostic LEDsYes

Product Description


The IC660BBS102 is a 115 VAC / 125 VDC Isolated I/O Block with eight circuits and Failed Switch Diagnostics by GE Fanuc. The IC660BBS102 is reported to continuously withstand 250 VAC/VDC between any group or ground or between any two groups. The block has a transient rating of 2000V peak for 10 seconds. Some configuarble features include AC/DC circuit voltage, defaults for output power-ups, CPU redundancy, a selectable input filter type ranging from 10mS to 100mS, capability for output pulse test, and module control for bus switching.

The block performs diagnostic tests that detect overload and no overload, I/O power loss on pairs of circuits, over-temperature, and open wire for tristate inputs. As long as terminals 5 and 6 are recieving power, the isolated I/O block should operate. Temperatures in excess of 100°C trigger an OVERTEMPERATURE message and turns off the circuit to protect the internal electronics of the unit. The short circuit level sensor at the switching device protects the output circuits. Outputs are configured to report No-Load conditions for a new block. Genius I/O blocks are considered "open equipment" and must be installed in a protective enclosure, clean and free of airborne contaminants and with adequate cooling airflow. The block can be mounted right side up, or upside down. Leave at least 2 inches of space between blocks. The block’s mounting screws must not be used as the only means of grounding the block.

The IC660BBS102 block is fully compatible with handheld monitor IC660HHM501 and any GE Fanuc bus controller. Blocks numbered IC660CBS100, 1C660BBS100, and IC660BBS101 are backward compatible with previous versions of this Genius I/O block. Terminal assembly model IC66*TSS100E is not compatible with earlier versions of the block. During field wiring, all terminal blocks can accommodate one AWG #12 or two AWG #14 wires. Terminals labeled 1 to 4 can accommodate ring terminals measuring up to 0.27 inches. Recommended torque for all terminals is 6 inches/lb.


Technical Specifications


Rated Voltage: 115 VAC / 125 VDC 
# of Points: 8
Input Voltage Range: 93 - 132 VAC
Output Voltage Range:    105 - 132 VDC
Load Current per Point:  2.0 Amps
Points per Common Four Groups of 2

 

The IC660BBS102 I/O block is a member of the GE Fanuc Genius I/O series. It is a GE Fanuc output block that has 8 outputs divided into 4 groups of 2. Isolation is available between all of the output groups. The IC660BBS102 output block can be connected to a hand-held monitor that the operators can use to program it or to monitor its applications. It supports CPU redundancy and voltage from either an AC source or a DC source. The nominal voltage ratings of the IC660BBS102 output block are 115 Volts AC and 125 Volts DC. It weighs about 4 pounds and its dimensions are 8.8 x 3.3 x 3.9 inches. During operation, this output block dissipates about 45.6 Watts of heat at peak.

 

The GE Fanuc Genius I/O IC660BBS102 output block needs to be installed on a terminal block that will be used to host all of its wiring. It is compatible with most of the contemporary terminal block models that are available from the GE Genius I/O series. All 8 of the block’s outputs feature electronic fusing that will shut down the block quickly (within 5 microseconds) if the outputs experience short circuits in order to protect the block and the rest of the circuits. After this shutdown, the IC660BBS102 output block can be restarted through either a handheld monitor if one is attached to it, or through the CPU of the Genius I/O system that it is part of. The load current rating for each output is 2 Amps. Its operating temperature range is from 32 to 140 degrees Fahrenheit, and its storage temperature range is from -40 to 212 degrees Fahrenheit.

Technical Information

Specifications

Block Type:

115VAC / 125VDCIsolatedI / OBlock: Terminal Assembly Only: ElectronicsAssemblyOnly:

115VAC / 125VDCIsolatedI / OBlock,NoFailed Switch: Terminal Assembly Only:

ElectronicsAssemblyOnly:

8 ckt isolated input / output in 4 isolated pairs IC660BBS102, replaces IC660BBS100 IC660TSS100

IC660EBS100

IC660BBS103, replaces IC660BBS101 IC660TSS100

IC660EBS101

Size (height x width x depth):

Weight:

LED’s (I/O Block): LED’s (each circuit): Block to Block Isolation: HeatDissipation:

8.83” (22.44cm) x 3.50” (8.89cm) x 3.94” x (10.00cm)

4 lbs. (1.8 kg)

Unit OK, I / OEnabled On logic side of switch 1500 V

16.8W max. with 8 inputs on, 45.6W max. with 8 outputs at 2 amps

Operating Temperature Storage Temperature Humidity

Vibration

–0   to   +60C   (32   to   +140F)

–40   C   (–40   to   +212F)

5% to 95% (non–condensing)

5–10 Hz 0.2” (5.08mm) displacement, 10–200 Hz at 1G

Required control power (block only):

Operating voltage (four sources): Frequency/ripple:

Power supply dropout time:

8 Wattsmaximum

93–132 VAC 105–132 VDC

47–63 Hz 10% max. ripple

1 cycle 10mS

Input Characteristics:

Non–tristate input, OFF state:

Minimum voltage across input device (IN to H) Maximum leakage through input device

Non–tristate input, ON state:

Maximum voltage across input device (IN to H) Maximumswitchcurrent threshold

Tristate input:

OFF, acceptable voltage across input device (IN to H) ON, maximum voltage across input device (IN to H)

Input load network: Resistor to N

Capacitor to H: for blocks BBS100 and BBS101 Capacitor to H: for blocks BBS102 and BBS103

Input processing time (typical)

Selectable input filter times Inputdiagnostics

For AC For DC

60 VRMS 70 VDC

1 mA 2 mA

20 VRMS 35 VDC

6 mA RMS 5 mA

16 VRMS–40 VRMS 16 VDC–35 VDC

4 VRMS 3.5 VDC

13K ohms 13K ohms

.22 f .22 f

.1 f .1 f

2mS + filter 0.8mS  + filter

10 to 100mS in 10mS increments

Open Wire, Overtemperature, Loss of I / O Power, Failed Switch

OutputCharacteristics: Output current (steady state) Maximum inrush current Output Leakage:

Current at 0 volt output: for blocks BBS102 and 103 Current at 0 volt output: for blocks BBS100 and 101 Voltage at open output: for blocks BBS102 and 103 Voltage at open output: for blocks BBS100 and 101

Output switch (OFF to ON / ON to OFF)

Rated switching frequency at maximum inrush Turn–on  delay (maximum)

Voltage drop (at 2 amps)

Voltage drop (at 20 amps inrush) Minimum load (No Load disabled)

Resistive: for blocks BBS102 and BBS103 Resistive: for blocks BBS100 and BBS101 Inductive: for blocks BBS102 and BBS103 Inductive: for blocks BBS100 and BBS101

No Load enabled threshold

Maximum block output current Fusing

Output diagnostics

For AC For DC

2 amps 2 amps resistive 9 (1 amp inductive*)

25 amps (2 cycles) 25 amps (10mS peak)

7 mA 2 mA

13mA 2 mA

65 volts 40 volts

95 volts 40 volts

Zerocrossing –––

Once per second Once per second

0.5 Hz + 1mS 1mS

2.5 volts 2.5 volts

10 volts 10 volts

25 mA 10 mA

30 mA 10 mA

40 mA 10 mA

100mA 10 mA

50 mA 50 mA

15 amps at 35   C, 7.5 amps   at 60C

Internal electronic short circuit trip. 100ms(AC), 10ms (DC) long time trip

Short Circuit, Overload, No Load, Overtemp., Loss of I / O Power.Also,

for blocks BBS100 and BBS 102 only: Failed Switch

Troubleshooting

Troubleshooting IC660BBS102

Troubleshooting information is available on IC660BBS102's website page; it also includes a datasheet user-manual and a wiring diagram.


Repair your IC660BBS102

PDF Supply can repair your IC660BBS102 in 3-5 business days. And PDF Supply stands by all of its repairs with a 1 year customer satisfaction warranty.

 

Customer Questions and Answers


  • Question:  What is an IC660BBS102?  Answer:  The IC660BBS102 is a 115 volt AC/125 volt DC, 8 circuit, Isolated I/O Block, with Failed Switch Diagnostics.
  • Question:  What does IC660BBS102 do?  Answer:  This block reports a Failed Switch diagnostic if any output's commanded state is not the same as the actual state of the block's own internal switch.
  • Question:  What is the isolation rated to withstand?   Answer:  It is rated to withstand 250 VAC/VDC continuous between any group and ground or between any 2 groups. 
  • Question:  What is the transient rating?  Answer:  It is 2000V peak for 10 seconds.
  • Question:  What are some of the features of IC660BBS102 that are up for configuration?  Answer:
    • AC/DC circuit voltage
    • Output Pulse Test capability
    • Selectable Input Filter Time from 10mS to 100mS
    • Output power up defaults
    • Output Hold Last State or default
    • CPU Redundancy type
    • Bus Switching module control
  • Question:  What diagnostic tests does this block perform?  Answer:
    • Over temperature Open Wire for tristate inputs
    • Detection of loss of I/O power on pairs of circuits
    • Overload detection and shutdown
    • No-load detection
  • Question:  What is my next step if my IC660BBS102 is not functioning properly?  Answer:  Your IC660BBS102 may need repair.

For more information on the IC660BBS102, 8 Circuit Isolated I/O Block of the GE Fanuc Genius I/O Series, please see the Datasheet User-Manual.

 

The final letter in the part number (ex. IC660BBS102K) indicates the revision. Revision K or later use the newer style electronic housing and therefore needs the newer style plastic door and may indicate some compatibility issues with the terminal strip.

ST. LOUIS, Feb. 1, 2019 – Emerson today announced it has completed the purchase of Intelligent Platforms from General Electric.

Common related search terms: ConfigurationDatasheetEmersonManualPDFPLCPriceRepairSpecificationTroubleshootUser-ManualWiring

PDF Supply sells used surplus products. PDF Supply is not an authorized distributor, affiliate, or representative for the brands we carry. Products sold by PDF Supply come with PDF Supply’s 1-year, 2-year, or 3-year warranty and do not come with the original manufacturer’s warranty. Designated trademarks, brand names and brands appearing herein are the property of their respective owners. This website is not sanctioned or approved by any manufacturer or tradename listed.

Rockwell Disclaimer: The product is used surplus. PDF Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because PDF Supply is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, PDF Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. PDF Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. PDF Supply also makes no representations as to your right to install any such firmware on the product. PDF Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.