GE / IP FANUC Series 90/30 In Stock

World's Largest Warehouse

of GE 90-30, Genius, and RX7i

Mon-Fri 8AM-5PM EST

IC660BBS100

Rated 4.5/5 Based on 4 ratings.

Rate your purchase of the IC660BBS100
IC660BBS100 In Stock! 115Vac/125Vdc Isolated I/O Block, 8 Circuit IC660B IC660BB IC660BBS PDFsupply

SKU 2172442  UPC 0912507793906

All product names, trademarks, brands and logos used on this site are the property of their respective owners. PDF Supply is not an authorized distributor, reseller or representative of the products featured on this website. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to in indicate any affiliation with or authorization by any rights holder.

PDF Supply is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply. Product comes with PDF Supply's 1-year, 2-year, or 3-year warranty.

New Surplus

$1842

2 In Stock

✓  3 Year PDF Supply Warranty

*What is New Surplus?

Ships .

Surplus New

$1599

Save $243

2 In Stock

✓  3 Year PDF Supply Warranty

*What is Surplus New?

Ships .

Reman

$1273

Save $569

138 In Stock

✓  2 Year PDF Supply Warranty

*What is Remanufactured?

Ships .

Repair Service

$1019

Save $823

5-10 Days

✓  2 Year PDF Supply Warranty

*What is Fast Repair?

Repair Completion:
5-10 Days

Common misspellings:
  • 1C660BBS100
  • IC66oBBS100
  • IC6608BS100
  • IC660B8S100
  • IC660BBSl00
  • IC660BBS1o0
  • IC660BBS10o
  • IC660BBS100

Technical Specifications for IC660BBS100

ManufacturerGE Fanuc
SeriesGenius I/O
Part NumberIC660BBS100
Product TypeI/O Block
Voltage Ratings115 Volts AC/125 Volts DC
Block to Block Isolation1500 Volts
Heat Dissipation16.8 Watts
FusingInternal electronic short circuit trip
Operating Temperature0 to 60 degrees Celsius
Weight (approx.)4 Pounds

**IC660BBS102 replaces IC660BBS100**

The IC660BBS100 is an isolated I/O Block manufactured by GE Fanuc that provides eight circuits in four isolated groups (each having two circuits). Its rated voltage is either 115 VAC or 125 VDC with a current of 2 Amps. The isolation is rated to withstand 250 VAC/VDC between any two groups.

Electronic fusing is built in for every circuit being used as an output. Should a short circuit occur, the circuit will shut down after five microseconds. However, the block can easily be restarted from the CPU or from a handheld monitor. Additional diagnostic checks performed by the block include unexpected shutdown, power overload, detection of load absence, and over temperature. An isolated block can be configured as input only, output only, or a combination of the two.

Each circuit comes with its own LED responsible for indicating threshold voltage for a circuit configured for input. For an output circuit, it indicates the mode configured by the CPU. Some of the configurable features of the IC660BBS100 block include bus switching control, presence of a dual power circuitry (i.e., both DC and AC circuitry), an input filter time that is easily selectable ranging from 10 ms to 100 ms, test capability of output pulse, and CPU redundancy type.

The block is 100% compatible with a hand-held monitor (models IC660HHM501 and IC660HHM500). IC660BBS100 is also compatible with any bus controller manufactured by GE Fanuc.  During field wiring, connections are made using simple tools such as standard screws and screwdrivers. Each terminal block accepts 1 AWG size #12 or two AWG #22 wires. Also accommodated are ring terminals with a width of up to 0.27 inches with a minimum opening for screw size #6. This block has been replaced by IC660BBS102.

The IC660BBS100 Isolated I/O Block belongs to the GE Fanuc Genius I/O series of I/O modules. It comes with 4 isolated groups of 2 I/O circuits each for a total of 8 I/O. It is compatible with the IC660HHM501 hand-held monitor which can be used for the configuration of the block. This I/O block is backward compatible with the previous block versions. The IC660BBS100 Isolated I/O Block has an LED to indicate the operating status of each of its I/O circuits. Additionally, each circuit of the module has a built-in thermal sensor. The block’s diagnostic facilities are made to report all the faults of the module to the hand-held programmer so that the users can take the necessary corrective actions as quickly as possible.    

 

The IC660BBS100 Isolated I/O Block has an I/O circuit which is rated to operate at a nominal voltage of 115 Volts AC or 125 Volts DC. It can perform a variety of diagnostic checks including no-load detection, over-temperature detection, open-wire detection for the tri state inputs, and overload detection, and it can shut down to protect itself.  This isolated I/O block can act as an input-only, output-only, or combination block. Once it is configured as an input-only block, all the circuits act as regular inputs and tri-state inputs. The configurable features of the IC660BBS100 Block are its output pulse test capability, CPU redundancy, bus switching module control, and selectable input filter times. It also comes with an internal electronic short circuit trip for safety. The heat dissipation rating of the module is 18.8 Watts. Its dimensions are 8.83 x 3.5 x 3.94 inches and its approximate weight is 4 pounds. It is recommended to configure the module as a combination block to have a mix of inputs and outputs.

Technical Information

Specifications

Block Type:

115VAC / 125VDCIsolatedI / OBlock: Terminal Assembly Only: ElectronicsAssemblyOnly:

115VAC / 125VDCIsolatedI / OBlock,NoFailed Switch: Terminal Assembly Only:

ElectronicsAssemblyOnly:

8 ckt isolated input / output in 4 isolated pairs IC660BBS102, replaces IC660BBS100 IC660TSS100

IC660EBS100

IC660BBS103, replaces IC660BBS101 IC660TSS100

IC660EBS101

Size (height x width x depth):

Weight:

LED’s (I/O Block): LED’s (each circuit): Block to Block Isolation: HeatDissipation:

8.83” (22.44cm) x 3.50” (8.89cm) x 3.94” x (10.00cm)

4 lbs. (1.8 kg)

Unit OK, I / OEnabled On logic side of switch 1500 V

16.8W max. with 8 inputs on, 45.6W max. with 8 outputs at 2 amps

Operating Temperature Storage Temperature Humidity

Vibration

–0   to   +60C   (32   to   +140F)

–40   C   (–40   to   +212F)

5% to 95% (non–condensing)

5–10 Hz 0.2” (5.08mm) displacement, 10–200 Hz at 1G

Required control power (block only):

Operating voltage (four sources): Frequency/ripple:

Power supply dropout time:

8 Wattsmaximum

93–132 VAC 105–132 VDC

47–63 Hz 10% max. ripple

1 cycle 10mS

Input Characteristics:

Non–tristate input, OFF state:

Minimum voltage across input device (IN to H) Maximum leakage through input device

Non–tristate input, ON state:

Maximum voltage across input device (IN to H) Maximumswitchcurrent threshold

Tristate input:

OFF, acceptable voltage across input device (IN to H) ON, maximum voltage across input device (IN to H)

Input load network: Resistor to N

Capacitor to H: for blocks BBS100 and BBS101 Capacitor to H: for blocks BBS102 and BBS103

Input processing time (typical)

Selectable input filter times Inputdiagnostics

For AC For DC

60 VRMS 70 VDC

1 mA 2 mA

20 VRMS 35 VDC

6 mA RMS 5 mA

16 VRMS–40 VRMS 16 VDC–35 VDC

4 VRMS 3.5 VDC

13K ohms 13K ohms

.22 f .22 f

.1 f .1 f

2mS + filter 0.8mS  + filter

10 to 100mS in 10mS increments

Open Wire, Overtemperature, Loss of I / O Power, Failed Switch

OutputCharacteristics: Output current (steady state) Maximum inrush current Output Leakage:

Current at 0 volt output: for blocks BBS102 and 103 Current at 0 volt output: for blocks BBS100 and 101 Voltage at open output: for blocks BBS102 and 103 Voltage at open output: for blocks BBS100 and 101

Output switch (OFF to ON / ON to OFF)

Rated switching frequency at maximum inrush Turn–on  delay (maximum)

Voltage drop (at 2 amps)

Voltage drop (at 20 amps inrush) Minimum load (No Load disabled)

Resistive: for blocks BBS102 and BBS103 Resistive: for blocks BBS100 and BBS101 Inductive: for blocks BBS102 and BBS103 Inductive: for blocks BBS100 and BBS101

No Load enabled threshold

Maximum block output current Fusing

Output diagnostics

For AC For DC

2 amps 2 amps resistive 9 (1 amp inductive*)

25 amps (2 cycles) 25 amps (10mS peak)

7 mA 2 mA

13mA 2 mA

65 volts 40 volts

95 volts 40 volts

Zerocrossing –––

Once per second Once per second

0.5 Hz + 1mS 1mS

2.5 volts 2.5 volts

10 volts 10 volts

25 mA 10 mA

30 mA 10 mA

40 mA 10 mA

100mA 10 mA

50 mA 50 mA

15 amps at 35   C, 7.5 amps   at 60C

Internal electronic short circuit trip. 100ms(AC), 10ms (DC) long time trip

Short Circuit, Overload, No Load, Overtemp., Loss of I / O Power.Also,

for blocks BBS100 and BBS 102 only: Failed Switch

 IC660BBS100 is a Phase B GE Genius block and is compatible with all GENIUS supported PLC systems. The earlier version- IC660CBS100 is a Phase A GE Genius Block and is only compatible with Series Six and Series Five PLCs.

 

The final letter in the part number (ex. IC660BBS100K) indicates the revision. Revision K or later use the newer style electronic housing and therefore needs the newer style plastic door and may indicate some compatibility issues with the terminal strip.

ST. LOUIS, Feb. 1, 2019 – Emerson today announced it has completed the purchase of Intelligent Platforms from General Electric.

Common related search terms: ConfigurationDatasheetEmersonManualPDFPLCPriceRepairSpecificationTroubleshootUser-ManualWiring

PDF Supply sells used surplus products. PDF Supply is not an authorized distributor, affiliate, or representative for the brands we carry. Products sold by PDF Supply come with PDF Supply’s 1-year, 2-year, or 3-year warranty and do not come with the original manufacturer’s warranty. Designated trademarks, brand names and brands appearing herein are the property of their respective owners. This website is not sanctioned or approved by any manufacturer or tradename listed.

Rockwell Disclaimer: The product is used surplus. PDF Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because PDF Supply is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, PDF Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. PDF Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. PDF Supply also makes no representations as to your right to install any such firmware on the product. PDF Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.