GE / IP FANUC Series 90/30 In Stock

World's Largest Warehouse

of GE 90-30, Genius, and RX7i

Mon-Fri 8AM-5PM EST

HE693RTD600

Rated 4.4/5 Based on 9 ratings.

Rate your purchase of the HE693RTD600
Horner Electric | Horner Electric | HE693RTD600 | Image

SKU 2177416  UPC 099465592526

All product names, trademarks, brands and logos used on this site are the property of their respective owners. PDF Supply is not an authorized distributor, reseller or representative of the products featured on this website. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to in indicate any affiliation with or authorization by any rights holder.

PDF Supply is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply. Product comes with PDF Supply's 1-year, 2-year, or 3-year warranty.

New Surplus

$1995

1 In Stock

✓  3 Year PDF Supply Warranty

*What is New Surplus?

Ships .

Reman

$630

Save $1,365

10 In Stock

✓  2 Year PDF Supply Warranty

*What is Remanufactured?

Ships .

Repair Service

$504

Save $1,491

5-10 Days

✓  2 Year PDF Supply Warranty

*What is Fast Repair?

Repair Completion:
5-10 Days

The HE693RTD600 allows RTD temperature sensors to be connected to the PLC directly without external signal processing such as transducers, transmitters, etc. All analog and digital processing on the module is performed on the HE693RTD600, and temperature values in 0.5°C or 0.5°F increments are written to the 90-30 %AI input table. All modules feature six channels, and support PT-90 (MIL-7990), PT-100 (alpha=.00385, .003902 and .03906), Ni-120, Cu-10, Cu-50, Cu-53, Cu-100, Pt-1000, TD5R and Linear Resistance.

Technical Specifications


Power Consumption (Typical) 75mA @ 5VDC
Number of Channels 6
I/O Points Required 6%AI
Input Impedance >1000 Meg Ω
Fault Protection Zener Diode Clamp
A/D Conversion Type 16 bit, Integrating
Update Time 50 Channels per second
Average RTD current, PT-100 330 microamps
Channel to Channel Tracking 0.1°C
Resolution 0.1°C
Accuracy ± 0.5°C typical, ± 1.0°C for Cu-10 and TD5R
Operating Temperature 0 to 60°C (32° to 140°F)
Relative Humidity 5% to 95% non-condensing

Technical Information

Power Consumption (Typical) 75mA @ 5VDC
Number of Channels 6
I/O Points Required 6%AI
Input Impedance >1000 Meg Ω
Fault Protection Zener Diode Clamp
A/D Conversion Type 16 bit, Integrating
Update Time 50 Channels per second
Average RTD current, PT-100 330 microamps
Channel to Channel Tracking 0.1°C
Resolution 0.1°C
Accuracy ± 0.5°C typical, ± 1.0°C for Cu-10 and TD5R
Operating Temperature 0 to 60°C (32° to 140°F)
Relative Humidity 5% to 95% non-condensing
  • Question: What is the HE693RTD600? Answer: The HE693RTD600 allows RTD temperature sensors to be connected to the PLC directly without external signal processing such as transducers, transmitters, etc. All analog and digital processing on the module is performed on the HE693RTD600, and temperature values in 0.5°C or 0.5°F increments are written to the 90-30 %AI input table. All modules feature six channels, and support PT-90 (MIL-7990), PT-100 (alpha=.00385, .003902 and .03906), Ni-120, Cu-10, Cu-50, Cu-53, Cu-100, Pt-1000, TD5R and Linear Resistance.
  • Question: What type of power consumption does HE693RTD600 use? Answer: The main power source for the HE693RTD600 uses 75mA @ 5VDC.
  • Question: How can I minimize capacitive loading and noise? Answer: Shielded, twisted-pair extension wiring offers the best noise immunity. 
  • Question: Where should the shields be connected to? Answer: If shielded wiring is used, a good earth ground connection (on one end only) is critical. If shields are connected at the module end, terminals 1 or 20 may be used as the shield ground point.
  • Question: Can I change the number of channels or the voltage on this device? Answer: Yes, you can. This is a 6 channel unit.

PDFsupply Tech

The HE693RTD600 contains 6 channels and has a typical power consumption of 75mA @ 5VDC, which is similar to the HE693RTD601.


PDF Supply sells used surplus products. PDF Supply is not an authorized distributor, affiliate, or representative for the brands we carry. Products sold by PDF Supply come with PDF Supply’s 1-year, 2-year, or 3-year warranty and do not come with the original manufacturer’s warranty. Designated trademarks, brand names and brands appearing herein are the property of their respective owners. This website is not sanctioned or approved by any manufacturer or tradename listed.

Rockwell Disclaimer: The product is used surplus. PDF Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because PDF Supply is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, PDF Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. PDF Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. PDF Supply also makes no representations as to your right to install any such firmware on the product. PDF Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.