GE / IP FANUC Series 90/30 In Stock

World's Largest Warehouse

of GE 90-30, Genius, and RX7i

Mon-Fri 8AM-5PM EST

HE693ADC816

Rated 4.5/5 Based on 7 ratings.

Rate your purchase of the HE693ADC816
Horner Electric | Horner Electric | HE693ADC816 | Image

SKU 2173157  UPC 0760508982689

All product names, trademarks, brands and logos used on this site are the property of their respective owners. PDF Supply is not an authorized distributor, reseller or representative of the products featured on this website. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to in indicate any affiliation with or authorization by any rights holder.

PDF Supply is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply. Product comes with PDF Supply's 1-year, 2-year, or 3-year warranty.

New Surplus

$2100

1 In Stock

✓  3 Year PDF Supply Warranty

*What is New Surplus?

Ships .

The Horner APG High-Speed +/-1mA Analog Input Module provides eight single-ended analog input channels which have 16-bits of resolution. The HE693ADC816-17 has 500VDC backplane isolation. This module converts the current input signals into digital values (0 to +32,000), which are placed directly into the %AI table of the PLC CPU. Each of the eight channels of the module has a programmable setpoint (the level of which is set in the PLC program via four %AQ output registers). When the analog input value reaches or exceeds the setpoint, a corresponding digital input %I is energized.

Technical Specifications


Power Consumption,Typical 230mA @ 5VDC (440mA inrush)
Number of Channels 8 single ended
I/O Required 8 %AI, 8 %AQ, 16 %I
Input Range +/- 1mA
A/D Type, Resolution Successive Approx. 16 bits
Useable Resolution 16 bits
Sample Rate 3000 channels/S, No Filtering*(See Installation Hints)
Input Impedance 10 kohms
Analog Filtering 1.6KHz low pass
Digital Filtering 1-128 samples / update
Maximum Error 0.1% full scale of+/-1 mA full scale
Maximum Input Voltage 75VDC
Backplane Isolation 500VDC
Common Mode Rejection >100dB
Relative Humidity 5% to 95%, non-condensing
Operating Temperature 0 to 60°C (32 to 140°F)

Technical Information

Power Consumption,Typical 230mA @ 5VDC (440mA inrush)
Number of Channels 8 single ended
I/O Required 8 %AI, 8 %AQ, 16 %I
Input Range +/- 1mA
A/D Type, Resolution Successive Approx. 16 bits
Useable Resolution 16 bits
Sample Rate 3000 channels/S, No Filtering*(See Installation Hints)
Input Impedance 10 kohms
Analog Filtering 1.6KHz low pass
Digital Filtering 1-128 samples / update
Maximum Error 0.1% full scale of+/-1 mA full scale
Maximum Input Voltage 75VDC
Backplane Isolation 500VDC
Common Mode Rejection >100dB
Relative Humidity 5% to 95%, non-condensing
Operating Temperature 0 to 60°C (32 to 140°F)
  • Question: What is a HE693ADC816? Answer: The HE693ADC816 provides eight single-ended input channels with 16-bits of resolution.
  • Question: What is the main power supply for the HE693ADC816? Answer: The main power source for this unit comes from 230mA @ 5VDC (440mA inrush) which is supplied by the PLC power supply. 
  • Question: How can I minimize capacitive loading and noise? Answer: Shielded, twisted-pair extension wiring offers the best noise immunity. 
  • Question: Where should the shields be connected to? Answer: Wiring needs to be routed in its own conduit. If shielded wiring is used, a good earth ground connection at one end is critical. If shields are grounded at the module end, terminals 19 and 20 should be used as the shield ground point. 
  • Question: Can I change the number of channels or the voltage on this device? Answer: Yes, you can. This is an 8 channel unit.
  • Question: What is a good way to test the HE693ADC410? Answer: The best method to test this unit is to use a +/-10Vdc power source to probe each channel for consistency and stability. 
  • Question: How to tell if your HE693ADC410 is faulty. Answer: Reference the response to each channel. Check for consistency and stability in the I/O tables. 

 

PDF Supply sells used surplus products. PDF Supply is not an authorized distributor, affiliate, or representative for the brands we carry. Products sold by PDF Supply come with PDF Supply’s 1-year, 2-year, or 3-year warranty and do not come with the original manufacturer’s warranty. Designated trademarks, brand names and brands appearing herein are the property of their respective owners. This website is not sanctioned or approved by any manufacturer or tradename listed.

Rockwell Disclaimer: The product is used surplus. PDF Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because PDF Supply is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, PDF Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. PDF Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. PDF Supply also makes no representations as to your right to install any such firmware on the product. PDF Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.