GE / IP FANUC Series 90/30 In Stock
SKU 2178122 UPC 0799705792937
All product names, trademarks, brands and logos used on this site are the property of their respective owners. PDF Supply is not an authorized distributor, reseller or representative of the products featured on this website. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to in indicate any affiliation with or authorization by any rights holder.
PDF Supply is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply. Product comes with PDF Supply's 1-year, 2-year, or 3-year warranty.
Other Available Revisions for the IC693ALG223 IC693ALG223-EAIC693ALG223-GBIC693ALG223AIC693ALG223BIC693ALG223CIC693ALG223-CAIC693ALG223DIC693ALG223-LTIC693ALG223-RR
Manufacturer | GE Fanuc |
---|---|
Series | Series 90-30 |
Part Number | IC693ALG223 |
Product Type | Input Module |
Number of Inputs | 16 |
Current Range | 4-20 mA, 0-20 mA |
Accuracy | 0.25 percent at 25 degrees Celsius |
Input Impedance | 250 Ohms |
Resolution at 4-20 mA | 4 microamps |
Resolution at 0-20 mA | 5 microamps |
IC693ALG223 is a PACSystems Series 90-30 RX3i Analog Current Input Module that offers 16 channels. The module’s 16 separate and single ended channels can be configured for any of the following three ranges: 4 to 20 mA, 0 to 20 mA, or 4 to 20 mA Enhanced. Both high and low alarms are obtainable on each range. In the enhanced range, the IC693ALG223 module can be set with a low alarm limit to detect input current with open wire fault detection in the 4 to 20 mA applications; high alarm alerts can also be set by the user. Additionally, this module reports status, including power supply standing to the CPU. IC693ALG223 can be used in any I/O slot that offers a serial connector in the RX3i or Series 90-30 system.
Specific to the IC693ALG223 module, 120 mA from a 5 VCD bus on the controller backplane is consumed. This also needs a 65 mA plus current loop from a +24 VDC supply supplied by the user. An update rate of 6 ms is standard with isolation of 250 VAC continuous or 1500 VAC for one minute. When scanning active channels, the number of channels to be scanned will be completed in serial order. Analog values are scaled over the entire range of the converter with factory calibration adjusting the analog value per bit. RX3i racks support upgrades to the firmware associated with this module, but this does not include 90-30 racks. The IC693ALG223 is also equipped with LED status lights emitting ON, OFF, and FAIL to assist the user in operation and troubleshooting.
No. of channels: | 1 to 16 selectable |
Input Current Range: | 0 to 20 mA, 4 to 20 mA and 4 to 20 mA enhanced |
Calibration:: | Factory calibrated to 4 µA per count or 5 µA per count |
Update Rate: | 13 msec (all 16 channels) |
Input Filter Response: | 19 Hz |
Power Consumption: | 120 mA from the +5 V bus or 65 mA from the +24 V bus |
Number of Channels |
1 to 16 selectable; single-ended |
Input Current Ranges |
0 to 20 mA, 4 to 20 mA and 4 to 20 mA Enhanced (selectable per channel) |
Calibration |
Factory calibrated to: 4 μA per count on 4 to 20 mA range 5 μA per count on 0 to 20 mA and 4 to 20 mA Enhanced range |
Update Rate |
Update Rate: 6 ms |
Resolution at 4–20 mA |
4 μA (4 μA/bit) |
Resolution at 0–20 mA |
5 μA (5 μA/bit) |
Resolution at 4–20 mA Enhanced |
5 μA (5 μA/bit) |
Absolute Accuracy 1 |
±0.25% of full scale @ 25°C (77°F): ± 0.5% of full scale over specified operating temperature range |
Linearity |
< 1 LSB from 4 to 20 mA (4 to 20 mA range) < 1 LSB from 100 μA to 20 mA (0 to 20 mA and 4 to 20 mA Enhanced ranges) |
Isolation, Field to Backplane (optical) and to frame ground |
250 VAC continuous; 1500 VAC for 1 minute |
Common Mode Voltage2 |
0 volts (single-ended channels) |
Cross–Channel Rejection |
> 70dB from DC to 1kHz |
Input Impedance |
250 W |
Input Low Pass Filter Response |
19 Hz |
External Supply Voltage Range |
20 to 30 VDC |
External Supply Voltage Ripple |
10% |
Internal Power Consumption |
120 mA from the +5 VDC bus on the backplane 65 mA from 24 VDC external user power supply (in addition to current loop currents) |
Troubleshooting information is available on IC693ALG223’s website page; it also includes a datasheet user-manual and a wiring diagram.
PDF Supply can repair your IC693ALG223 in 3-5 business days. And PDF Supply stands by all of its repairs with a 1 year customer satisfaction warranty.
User Supply OK Status Bit for IC693ALG223
Description
Advisory Concerning Use Of "User Supply OK" Status Bit For The Series 90™-30 IC693ALG223A Analog Current Input Module
Resolution
The Series 90-30 16 channel Analog Current Input Module (IC693ALG223) provides 1500V isolation between the field wiring and the PLC logic circuitry by means of an optocoupler barrier. This module requires an external DC power supply for the analog and digital circuitry on the field side of that barrier. If the user-provided external power supply (+24VDC nominal) fails, is disconnected, or otherwise falls outside of the allowable range then the initial version (with catalog number suffix 'A') of this module will do the following:
CAUTION
The artificial full scale value (+32760) that is reported to the PLC when the external DC power supply goes out of the allowed range may cause unexpected PLC logic solution if the "User Supply OK" status bit is not monitored by the user's application program to prevent this value from being interpreted as valid.
NOTE
The "User Supply OK" and "Module OK" status bits should always be used to help ensure that the application program handles unexpected events such as the loss of external power supplies in a suitable manner. For additional information on the application or capabilities of this particular Series 90-30 module, refer to datasheet GFK-0831.
· For more information on the IC693ALG223 Analog Input Module of the GE 90-30 Series, please see the Datasheet Manual.
Version |
Firmware Release |
Date |
Description |
IC694ALG223-DB IC693ALG223-GB |
1.60 |
May 2012 |
Resolves several rarely-occuring issues that were identified in field and factory testing. |
IC694ALG223-BA IC693ALG223-EA |
1.1 |
Apr. 2011 |
Adds ability to perform field upgrades in RX3i targets. Adds display of module serial number, revision and date code in programming software in RX3i targets. |
Common related search terms: BuyDatasheet, Emerson, Manual, Price, Repair, Specification, Troubleshoot, Wiring,
PDF Supply sells used surplus products. PDF Supply is not an authorized distributor, affiliate, or representative for the brands we carry. Products sold by PDF Supply come with PDF Supply’s 1-year, 2-year, or 3-year warranty and do not come with the original manufacturer’s warranty. Designated trademarks, brand names and brands appearing herein are the property of their respective owners. This website is not sanctioned or approved by any manufacturer or tradename listed.
Rockwell Disclaimer: The product is used surplus. PDF Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because PDF Supply is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, PDF Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. PDF Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. PDF Supply also makes no representations as to your right to install any such firmware on the product. PDF Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.